Fire Officer Chapter 6

Doug Wade's profile picture
Created by
Doug Wade

What are the two primary methods of built-in fire protection used in large cities built in the late 1880s?

Compartmentation and automatic fire sprinklers

What is compartmentation in fire protection?

A passive fire protection method using fire-rated floors, walls, and protection of vertical openings.

What defines an automatic fire sprinkler system?

An active fire protection method requiring action or motion to operate effectively during a fire.

What are the five most common issues found during a pre-incident plan or code enforcement visit?

Blocked access to fire department connections, improper storage in pump and riser rooms, items hanging from sprinklers, insufficient clearance for sprinklers, and incorrect sprinkler coverage.

What are the six considerations outlined in NFPA 1620 for completing a pre-incident plan?

Physical elements and site considerations, occupancy considerations, water supply and fire protection systems, special considerations, emergency operation considerations, and documenting findings.

What is a plot plan in the context of fire safety?

A representation of the exterior of a structure identifying site access, doors, utilities access, and hazards.

How do floor plans differ from plot plans?

Floor plans provide interior views of a building, showing the arrangement of rooms and features.

What is the purpose of building codes?

To regulate the construction of new buildings or major renovations.

What does fire code apply to?

Existing buildings and situations involving potential fire risks or hazards.

What are the three classes of standpipes based on their expected use?

Class I, Class II, and Class III.

Name four types of special extinguishing systems.

Carbon dioxide, dry or wet chemical, Halon/clean agent, and foam.

What defines an assembly occupancy?

A space used for gathering people for activities like deliberation, worship, entertainment, or transportation.

Describe an industrial occupancy.

A space where products are manufactured or processing operations are conducted.

What characterizes institutional occupancy?

Facilities used for medical treatment or care of individuals incapable of self-preservation.

What is the significance of NFPA 1021, Standard for Fire Officer Professional Qualifications?

It includes performing fire investigations to determine the area of origin and preliminary cause.

1 of 15

Make a Copy
Download Cards
Generate Quiz
Exam Mode

Description

Discover essential fire protection methods, common pre-incident issues, and the importance of building codes in fire safety. Learn about compartmentation, automatic sprinklers, and special extinguishing systems for effective fire management.

1. What type of occupancy provides sleeping accommodations for purposes other than health care, detention, or corrections?

A Residential occupancy B Institutional occupancy C Educational occupancy D Mercantile occupancy

2. What is compartmentation in fire protection?

A A passive fire protection method using fire-rated floors and walls. B A technique for blocking access to fire department connections. C A method involving only fire alarm systems. D An active fire protection method using sprinklers.

3. Which of the following is an example of an active fire protection method?

A Fire-rated walls. B Fire-resistive construction. C Automatic fire sprinkler system. D Compartmentation.

4. What are the two primary methods used in big cities for built-in fire protection in the late 1880s?

A Compartmentation and automatic fire sprinklers. B Fire-rated columns and beams. C Fire alarms and fire walls. D Vertical opening protection and fire partitions.

5. What is a common issue found during a pre-incident plan or code enforcement visit?

A Unblocked access to exits. B Blocked access to fire department system connections. C Proper storage in the fire area. D Adequate fire alarm systems.

6. Why is an automatic fire sprinkler system considered an active fire protection method?

A It involves the use of fire walls and partitions. B It requires action or motion to work effectively in the event of a fire. C It uses fire-rated materials to prevent collapse. D It is always operational without any action.

7. What is a common issue related to fire sprinklers found during a pre-incident plan or code enforcement visit?

A Blocked access to fire department system connections B Not enough clearance to allow a fire sprinkler to fully operate C Improper storage in the fire pump and riser rooms D Items hanging from fire sprinklers and piping

8. Why is it important to maintain enough clearance around fire sprinklers?

A To avoid blocked access to system connections B To prevent items from hanging on them C To allow the fire sprinkler to fully operate D To ensure proper storage in pump rooms

9. What should not be stored in the fire pump and riser rooms?

A Improper storage items B Fire department system connections C Clearance space D Fire sprinklers and piping

10. What is one of the most common issues discovered during a pre-incident plan or code enforcement visit?

A Items hanging from fire sprinklers B Improper storage in riser rooms C Blocked access to fire department system connections D Not enough clearance for sprinklers

11. What does a plot plan represent in a pre-incident plan?

A The water supply and fire protection systems. B The regulations for constructing new buildings. C The exterior of a structure, identifying site access, doors, utilities access, and any special considerations or hazards. D The interior layout of rooms and hallways.

12. What is the purpose of NFPA 1620 in fire safety planning?

A To specify the requirements for fire sprinkler systems. B To outline considerations for completing a pre-incident plan. C To provide regulations for new building construction. D To document the findings of fire investigations.

13. What do floor plans depict in the context of fire safety planning?

A Special considerations and hazards outside the building. B The water supply and fire protection systems. C Interior views of a building, showing rooms, hallways, and other features in correct relationship to each other. D The exterior layout including site access and utilities.

14. Which code applies to existing buildings and situations involving potential fire risks?

A Building code B Fire code C Electrical code D Plumbing code

15. What is one of the six considerations outlined by NFPA 1620 for pre-incident planning?

A Identify electrical wiring standards. B Identify HVAC system efficiency. C Identify physical elements and site considerations. D Identify landscaping requirements.

16. What is a common requirement for new buildings according to the building code?

A Maximum number of floors. B Maximum number of rooms. C Minimum number of windows. D Minimum number of exits.

17. What type of hose coupling does Class II provide in a hose station cabinet?

A 2-inch (50-mm) B 1-inch (25-mm) C 2.5-inch (65-mm) D 1.5-inch (38-mm)

18. Which special extinguishing system uses a gas to suppress fires?

A carbon dioxide B foam C wet chemical D dry chemical

19. What is an assembly occupancy used for?

A Storage of goods B Account and record keeping C Transaction of business D Gathering of people for deliberation, worship, entertainment, eating, drinking, amusement, or awaiting transportation.

20. What type of connection does Class III provide for occupant use until the fire department arrives?

A 2.5-inch (65-mm) connection B 2-inch (50-mm) connection C 1-inch (25-mm) connection D 1.5-inch (38-mm) connection

21. What is an example of improper storage in the context of fire safety inspections?

A Blocking system connections B Not maintaining clearance C Storing items in the fire pump room D Hanging items from sprinklers

22. What is required by the building code in a new building for fire protection?

A Only automatic sprinklers and a fire alarm system. B Installation of automatic sprinklers, a fire alarm system, and a minimum number of exits. C Only automatic sprinklers and exits. D Only a fire alarm system and exits.

23. Which class of standpipe is intended for use by fire department or fire brigade members trained in the use of large hose streams?

A Class III B Class II C Class IV D Class I

24. To which types of buildings does the fire code apply?

A Only renovated buildings. B Only buildings under construction. C Existing buildings and situations involving potential fire risks. D Only new buildings.

25. What is the primary purpose of a standpipe system in a building?

A To control the spread of fire. B To alert occupants of a fire. C To provide water for firefighting purposes. D To detect smoke.

26. Which occupancy type is used for account and record keeping or transaction of business other than mercantile?

A Residential occupancy B Storage occupancy C Business occupancy D Assembly occupancy

27. What type of occupancy is used for educational purposes through the 12th grade?

A Institutional occupancy B Educational occupancy C Industrial occupancy D Mercantile occupancy

28. Which type of occupancy involves manufacturing or processing operations?

A Institutional occupancy B Industrial occupancy C Educational occupancy D Residential occupancy

29. What type of occupancy is used for medical treatment or care of persons mostly incapable of self-preservation?

A Industrial occupancy B Institutional occupancy C Educational occupancy D Mercantile occupancy

30. Which type of occupancy is used for the display and sale of merchandise?

A Mercantile occupancy B Residential occupancy C Institutional occupancy D Industrial occupancy

Study Notes

Overview of Fire Safety Principles and Practices

This document consolidates key concepts related to fire safety, focusing on built-in protection methods, occupancy classifications, regulatory compliance, and investigation procedures. Understanding these elements is crucial for enhancing safety in various environments.

Built-in Fire Protection

  • Fire Protection Methods: Includes passive strategies like compartmentation (fire-rated barriers) and active measures such as automatic sprinklers.
  • Importance of Pre-Incident Planning: Regular assessments identify hazards and ensure compliance with safety codes, improving overall fire readiness.

Occupancy Types and Regulations

  • Classification of Occupancies: Different types include educational, industrial, institutional, mercantile, residential, storage, mixed-use properties, and special properties. Each type has specific safety requirements.
  • Building and Fire Codes: New constructions must meet stringent building codes for features like sprinklers and alarms; fire codes apply to existing structures to mitigate risks.

Fire Safety Systems

  • Hose Couplings and Extinguishing Systems: Class II couplings are for occupant use; Class III includes larger connections for trained personnel. Special extinguishing systems (e.g., CO2, foam) are tailored for specific applications.
  • Accessibility Issues: Ensuring clear access to fire department connections is vital for effective emergency response.

Code Compliance Inspections

  • Purpose of Inspections: Conducted in public assembly areas to ensure clear exit pathways and adherence to storage regulations that prevent hazards.
  • Overcrowding Concerns: Inspections address overcrowding risks that could impede safe evacuations during emergencies.

Fire Investigation Procedures

  • Entry Without Warrant: Firefighters can enter a scene without a search warrant during initial responses but need administrative or criminal warrants for further investigations.
  • Evidence Collection Protocols: Understanding the legal distinctions between types of warrants ensures proper evidence handling post-fire incident.

Key Takeaways

  1. Effective fire safety relies on both built-in protection methods and regular pre-incident planning.
  2. Understanding occupancy classifications helps ensure compliance with relevant building codes tailored to specific uses.
  3. Proper inspection protocols are essential in maintaining safety standards in public spaces while also guiding lawful fire investigation procedures.